| Weight | .09680 lb | ||
| lead wire | connector type | ||
| Port size | 01: r 1/8, m5 x 0.8 t1: nptf 1/8, m5 x 0.80x: with suction filter (for mounting on zx unit) 0r: base mount type (for mounting on zr unit) | ||
| withstand voltage | 1000 vac for 1 min. (between live parts and case) | ||
| resistance | impact resistance | ||
| response time | 5 ms or less | ||
| power supply voltage | 12 to 24 vdc ?10%, ripple (p-p) 10% or less (with power supply polarity protection) | ||
| proof pressure | 500 kpa | ||
| model | for vacuum |
| Standard | compliant with ce marking | ||
| mass | 35 g (including 0.6 m-long lead wire) | ||
| insulation resistance | 50 m or more (at 500 vdc by megameter) between live parts and case | ||
| temperature characteristics(based on 25c) | ?3% f.s. or less | ||
| repeatability | ?1% f.s. or less | ||
| Current consumption | 17 ma or less at 24 vdc | ||
| fluid | air/non-corrosive, non-flammable gas | ||
| rated pressure range/set pressure range | 0 to ?101 kpa |