| Material housing | Wrought aluminium alloy Smooth anodised | ||
| Material cover | Wrought aluminium alloy Anodised | ||
| Note on materials | RoHS-compliant | ||
| Type of mounting | With through-hole Via female thread Either: | ||
| Theoretical torque at 0.6 MPa (6 bar, 87 psi) | 2,41 Nm | ||
| LABS (PWIS) conformity | VDMA24364 zone III | ||
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
| Explosion ignition protection type for dust | Ex h IIIC T120°C Db | ||
| ATEX category dust | II 2D | ||
| Explosion protection | Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) | ||
| CE marking (see declaration of conformity) | To UK EX instructions | ||
| Mode of operation | Double-acting | ||
| Symbol | 00991265 | ||
| Max. number of intermediate positions | 1 | ||
| Mounting position | optional | ||
| Swivel angle | 180 deg |
| Material seals | NBR TPE-U(PU) | ||
| Material drive shaft | Tempered steel | ||
| Pneumatic connection | M5 | ||
| Permissible mass moment of inertia | 0,04 kgm² ... 0,15 kgm² | ||
| Ambient temperature | -10 °C ... 60 °C | ||
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
| Explosion ambient temperature | -10°C <= Ta <= +60°C | ||
| Explosion ignition protection type for gas | Ex h IIC T4 Gb | ||
| ATEX category gas | II 2G | ||
| Explosion protection certification outside the EU | EPL Db (GB) EPL Gb (GB) | ||
| CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) | ||
| Operating pressure | 2 bar ... 10 bar | ||
| Position detection | Via proximity switch | ||
| Design | Rack and pinion | ||
| Cushioning | Elastic cushioning rings/plates at both ends External hydraulic cushioning Internal hydraulic cushioning, soft Internal hydraulic cushioning normal | ||
| Size | 20 |