Specifications
| Series (SFAH) | Flow sensor |
|---|---|
| Flow measuring range (50) | Max. 50 l/min |
| Flow rate input (U) | Unidirectional |
| Pneumatic connection (Q6) | Push-in connector 6 mm |
| Thread type | None |
| Outlet orientation (AR) | Angled, adjustable |
| Electrical output 1 (PNLK) | PNP/NPN/IO-Link |
| Electrical output 2 (PNVBA) | PNP or NPN or 0 ... 10 V or 1 ... 5 V or 4 ... 20 mA |
|---|---|
| Electrical connection (M8) | Plug M8, A-coded |
| Mounting accessories | None |
| Electrical accessories | None |
| Protective devices | None |
| Certifi cate | None |
| LABS (PWIS) conformity | VDMA24364-B2-L | ||
| Protection class | III | ||
| Degree of protection | IP40 | ||
| Setting options | IO-Link® Teach-in Via display and keys | ||
| Display type | Illuminated LCD, multi-colour | ||
| Material housing | PA-reinforced | ||
| Pneumatic connection, outlet direction | Angled, adjustable | ||
| Mounting position | optional | ||
| Electrical connection 1, connection pattern | 00991171 | ||
| Electrical connection 1, connector system | M8x1, A-coded, to EN 61076-2-104 | ||
| Reverse polarity protection | For all electrical connections | ||
| Operational voltage range DC | 22 V ... 26 V | ||
| IO-Link, Min. cycle time | 4 ms | ||
| IO-Link, Process data content IN | 1 bit BDC (volume monitoring) 14 bit PDV (measured flow value) 2 bit BDC (flow monitoring) | ||
| IO-Link, Port class | A | ||
| IO-Link, communication mode | COM2 (38.4 kBaud) | ||
| IO-Link, Profile | Smart sensor profile | ||
| Protocol | IO-Link® | ||
| Short circuit current rating | yes | ||
| Max. load resistance current output | 500 Ohm | ||
| Flow characteristic curve start value | 0 l/min | ||
| Max. output current | 100 mA | ||
| Switching function | Window comparator Threshold value comparator Auto difference monitoring | ||
| Pressure influence span in ± %FS/bar | 1 %FS/b. | ||
| Repetition accuracy span in ± %FS | 0,8 %FS | ||
| Accuracy of flow rate | ± (2% o.m.v. + 1% FS) | ||
| Ambient temperature | 0 °C ... 50 °C | ||
| Operating medium | Argon Compressed air to ISO 8573-1:2010 [6:4:4] Nitrogen | ||
| End value for flow rate measuring range | 50 l/min | ||
| Measurement method | Heat transfer | ||
| Flow direction | Unidirectional | ||
| Note on materials | RoHS-compliant | ||
| CE marking (see declaration of conformity) | To UK instructions for EMC To UK RoHS instructions | ||
| Approval | RCM trademark c UL us listed (OL) |
| Corrosion resistance class CRC | 2 - Moderate corrosion stress | ||
| Pressure drop | 12 mbar | ||
| Protection against tampering | IO-Link PIN code | ||
| Displayable units | g g/min l l/min scft scft/h scft/min | ||
| Material in contact with the medium | Anodised wrought aluminium alloy Epoxy NBR PA-reinforced Silicon Silicon nitride High-alloy stainless steel | ||
| Product weight | 60 g | ||
| Pneumatic connection | For tubing O.D. 6 mm | ||
| Type of mounting | With accessories | ||
| Electrical connection 1, number of connections/cores | 4 | ||
| Electrical connection 1, connection type | Plugs | ||
| No-load supply current | ≤ 25 mA | ||
| IO-Link, Data storage required | < 500 Byte | ||
| IO-Link, Service data IN | 32-bit volume/mass measurement | ||
| IO-Link, Process data length IN | 3 bytes | ||
| IO-Link, SIO-Mode support | Yes | ||
| IO-Link, Function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel | ||
| IO-Link, Protocol version | Device V 1.1 | ||
| Overload protection | Available | ||
| Min. load resistance voltage output | 20 kOhm | ||
| Flow characteristic curve end value | 50 l/min | ||
| Analogue output | 0 - 10 V 4 - 20 mA 1 - 5 V | ||
| Switching element function | N/C or N/O contact, switchable | ||
| Switching output | 2 x PNP or 2 x NPN, switchable | ||
| Temperature coefficient span in ± %FS/K | Typ. 0.15%FS/K | ||
| Repetition accuracy offset in ± %FS | 0,2 %FS | ||
| Nominal temperature | 23 °C | ||
| Media temperature | 0 °C ... 50 °C | ||
| Operating pressure | -0,9 bar ... 10 bar | ||
| Start value for flow rate measuring range | 1 l/min | ||
| Measuring principle | Thermal | ||
| Measured variable | Mass flow rate Volumetric flow rate | ||
| Certificate issuing authority | UL E322346 | ||
| CE mark (see declaration of conformity) | To EU EMC Directive In accordance with EU RoHS Directive | ||
| Symbol | 00995794 |