| Version | bus coupler | ||
| fieldbus protocol | powerlink | ||
| number of i/o connections | 512 inputs / 512 outputs | ||
| power plug in size | m12x1 | ||
| power plug in coding | a-coded | ||
| min. ambient temperature | -10 °c | ||
| number of solenoid coils max. | 128 | ||
| operational voltage electronics | 24 v dc | ||
| current consumption electronics | 0.1 a | ||
| total output for valves | 4 a | ||
| cycle time at 256 bits | < 1 ms | ||
| Diagnosis | system error, undervoltage | ||
| generic emission standard in accordance with norm | en 61000-6-4 |
| Note | do not use in new constructions! | ||
| e/a capable | connection with i/o | ||
| power plug in type | plug | ||
| power plug in number of pole | 4-pin | ||
| fieldbus design | d-design | ||
| max. ambient temperature | 60 °c | ||
| Max. number of valve positions | 64 | ||
| electronics voltage tolerance | -25% / +25% | ||
| operating voltage, actuators | 24 v dc | ||
| Protection class | ip65 | ||
| logic/actuator voltage | galvanically isolated | ||
| i/o module extension max. | 10 |