| Material winding | Copper | ||
| Note on materials | RoHS-compliant | ||
| Electrical connection | 3-pin Plug pins with connection pattern to Festo standard for MSSD-F | ||
| Max. tightening torque for socket | 0,4 Nm | ||
| Degree of protection | IP65 | ||
| Explosion ignition protection type for dust | Ex tc IIIC T130°C X Dc IP65 | ||
| ATEX category dust | II 3D | ||
| Explosion protection | Zone 2 (ATEX) Zone 22 (ATEX) Zone 2 (CN) Zone 22 (CN) | ||
| CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) To EU Low Voltage Directive | ||
| Permissible frequency fluctuations | +/- 5% | ||
| Power factor (cos phi) | 0,7 | ||
| Min. pick-up time | 10 ms |
| Material solenoid coil | Duroplast Copper Steel | ||
| Type of mounting | Via knurled nut | ||
| Product weight | 55 g | ||
| Ambient temperature | -5 °C ... 40 °C | ||
| Explosion ambient temperature | -5°C <= Ta <= +40°C | ||
| Explosion ignition protection type for gas | Ex nA IIC T4 X Gc | ||
| ATEX category gas | II 3G | ||
| Explosion protection certification outside the EU | EPL Dc (CN) EPL Gc (CN) | ||
| Permissible voltage fluctuations | +/- 10 % | ||
| Characteristic coil data | 110 V AC: 50/60 Hz, pick-up power 9.0 VA, holding power 7.0 VA | ||
| Duty cycle | 100% | ||
| Mounting position | optional |