| flow rate | 9 gal/min, 34 l/min | ||
| pressure control range | 30-2400 psi, 2-166 bar | ||
| seal material | nitrile | ||
| division | mobile systems division europe | ||
| maximum operating pressure | 6000 psi, 420 bar | ||
| standard setting pressure | 1160 psi, 80 bar | ||
| pressure control sensitivity | 248 per turn psi, 17 per turn bar | ||
| drain option | internal | ||
| Mounting type | screw in cartridge valve | ||
| configuration | normally closed | ||
| function | direct acting sequence | ||
| for fluid type | mineral-based or synthetic hydraulic fluids | ||
| filter efficiency rating | iso 4406 18/16/13, sae class 4 | ||
| installation torque | 50 nm, 37 lb-ft | ||
| maximum operating temperature | +250 °f, +121 °c | ||
| Weight | 0.66 lb, 0.3 kg |
| maximum inlet pressure rating | 6000 psi, 420 bar | ||
| adjustment mechanism | screw | ||
| sealed pilot included | no | ||
| maximum flow rate | 9 gal/min, 34 l/min | ||
| maximum tank pressure | 6000 psi, 420 bar | ||
| maximum pressure setting | 2400 psi, 166 bar | ||
| leak rate | 25 @ 1450 psi (100 bar) cm3/min | ||
| pilot location | external | ||
| actuation type | pressure sensing | ||
| cavity size | c10-3 | ||
| operation type | automatic | ||
| maximum kinematic viscosity | 45-2000 ssu (6 to 420 cst) | ||
| valve material | all parts steel. all operating parts hardened steel | ||
| Operating temperature | -30 to +250 °f, -34 to +121 °c | ||
| minimum operating temperature | -30 °f, -34 °c |
| Stock | Ask for quotation |
|---|---|
| Part number | B04F3GZN |
| Manufacturer | PARKER |
| Quantity | Unit Price |
|---|---|
| 1+ | £70.83 |