| Material cylinder barrel | Wrought aluminium alloy Smooth anodised | ||
| Material cover | Aluminium Anodised | ||
| Pneumatic connection | G1/8 | ||
| Additional weight per 10 mm stroke | 37 g | ||
| Additional moving mass per 10 mm stroke | 9 g | ||
| Theoretical force at 0.6 MPa (6 bar, 87 psi), advance stroke | 686 N ... 754 N | ||
| Ambient temperature | -40 °C ... 120 °C | ||
| Suitability for the production of Li-ion batteries | Metals with more than 1% copper, zinc or nickel by mass are excluded from use. Exceptions are nickel in steel, chemically nickel-plated surfaces, printed circuit boards, cables, electrical plug connectors and coils | ||
| Corrosion resistance class CRC | 0 - No corrosion stress 2 - Moderate corrosion stress 3 - high corrosion stress | ||
| Operating medium | Compressed air to ISO 8573-1:2010 [7:4:4] | ||
| Explosion ignition protection type for dust | Ex h IIIC T120°C Db | ||
| ATEX category dust | II 2D | ||
| Explosion protection | Zone 1 (ATEX) Zone 2 (ATEX) Zone 21 (ATEX) Zone 22 (ATEX) | ||
| CE mark (see declaration of conformity) | To EU Explosion Protection Directive (ATEX) | ||
| Operating pressure | 0,6 bar ... 10 bar | ||
| Design | Piston Piston rod Profile barrel | ||
| Cushioning | Elastic cushioning rings/plates at both ends Self-adjusting pneumatic end-position cushioning | ||
| Piston diameter | 40 mm |
| Material piston rod | High-alloy steel | ||
| Note on materials | RoHS-compliant | ||
| Type of mounting | With through-hole Via female thread With accessories Either: | ||
| Basic weight for 0 mm stroke | 346 g | ||
| Moving mass for 0 mm stroke | 80 g | ||
| Theoretical force at 0.6 MPa (6 bar, 87 psi), return stroke | 686 N | ||
| Cleanroom class | Class 4 according to ISO 14644-1 Class 5 according to ISO 14644-1 | ||
| LABS (PWIS) conformity | VDMA24364-B1/B2-L VDMA24364 zone III | ||
| Note on operating and pilot medium | Lubricated operation possible (in which case lubricated operation will always be required) | ||
| Explosion ambient temperature | -20°C <= Ta <= +60°C | ||
| Explosion ignition protection type for gas | Ex h IIC T4 Gb | ||
| ATEX category gas | II 2G | ||
| CE marking (see declaration of conformity) | To UK EX instructions | ||
| Mode of operation | Double-acting | ||
| Position detection | Via proximity switch | ||
| Mounting position | optional | ||
| Based on standard | ISO 21287 | ||
| Stroke | 1 mm ... 400 mm |