| medium-contacting part stopper material | stainless steel | ||
| rated power ac | 9 v·a | ||
| reduced power dc | 9 w | ||
| thermal insulation class of the actuator | h | ||
| coil wiring polarity protection | yes | ||
| coil wiring overvoltage protection | suppressor diode | ||
| coil insulation material (encasement) | epoxy | ||
| kick and drop coil | energy saving technology included | ||
| cable plug art. no. - type | 00314802 - 2518 | ||
| cable plug in delivery | enclosed | ||
| installation length | 100 mm | ||
| nominal operation/duty cycle | 100 % | ||
| switch time close min | 700 ms | ||
| switch time open min | 100 ms | ||
| valve construction | valve complete | ||
| flow | above seat | ||
| actuator type | plunger valve | ||
| main valve orifice 1 (inch) | 3/4 inch | ||
| pilot control orifice (mm) | 2 mm | ||
| kv value (water) | 6,5 m3/h | ||
| pilot control seal material | nbr (nitrile rubber) | ||
| seat seal material | nbr (nitrile rubber) | ||
| temperature environment max | 55 °c | ||
| temperature medium min | -10 °c | ||
| nominal pressure min | 0 bar | ||
| battery voltage | yes | ||
| ac voltage | yes | ||
| voltage tolerance positive | 10 % | ||
| voltage max / rated voltage | 24 v | ||
| port connection 2 thread marking | 3/4 | ||
| port connection 2 type | inner thread | ||
| port connection 1 thread marking | 3/4 | ||
| Valve function | a - normally closed - inlet port 1 (p/nc) | ||
| fluidic port connection number | 2 |
| medium-contacting part core material | stainless steel | ||
| inrush power consumption ac | 100 v·a | ||
| rated power dc | 100 w | ||
| coil wiring polarity recovery diode | yes | ||
| coil wiring rectifier | yes | ||
| coil size | 49 mm | ||
| coil type | block bolted | ||
| protection type ip (max. with suitable connector) | ip65 | ||
| electrical connection position | in direction of flow left | ||
| electrical connection number of contacts | 2 + grounding conductor | ||
| vacuum version | yes | ||
| switch time close max. | 2.000 ms | ||
| switch time open max. | 250 ms | ||
| switch function | on/off | ||
| main valve operating principle | diaphragm valve | ||
| operation | force-controlled | ||
| Type | 290 | ||
| main valve orifice 1 (p) (mm) | 20 mm | ||
| qnn value (gas) | 7.000 l/min | ||
| rated power consumption | 100 w | ||
| sealing toward outside material | nbr (nitrile rubber) | ||
| seat seal material category | elastomer | ||
| temperature medium max | 80 °c | ||
| nominal pressure max (liquid) | 16 bar | ||
| main valve wetted material | brass | ||
| dc voltage | yes | ||
| voltage tolerance negative | 10 % | ||
| voltage frequency | 50/60 hz | ||
| voltage min / rated voltage | 24 v | ||
| port connection 2 thread type | g | ||
| port connection 1 thread type | g | ||
| port connection 1 type | inner thread | ||
| valve function number of switching positions | 2 | ||
| Customscode | 84818079 |